Medpharm H2O2 Low Temperature Plasma Sterilizers provide an efficient sterilization solution for heat & moisture sensitive instruments or devices in CSSDs, Clinics and Laboratories.
Low Temperature Hydrogen Peroxide Plasma Sterilizer For Heat-sencitive Apparatus
Medpharm H2O2 Low Temperature Plasma Sterilizers provide an efficient sterilization solution for heat & moisture sensitive instruments or devices in CSSDs, Clinics and Laboratories.
Advantages
Low temperature sterilization
The sterilizing temperature range is 50±5℃. Adopts dry sterilization which has no injury on instruments so that extends the instrument service life.
Safe and environment friendly
The agents of sterilization are water and oxygen molecule that have no toxic harm to staff or patient, and there is no special need for drainage or air exhausting. The high efficient H2O2 filler is installed in the exhausting outlet to guarantee no H2O2 pollution to the environment.
Time-saving and cost-efficient
Rectangular chamber has greater capacity, high efficiency and short sterilizing cycle (≤50mins). The sterilized articles can be used directly without extra processing. This can increase the instrument turnover efficiency and decrease the storage of precious instrument to cut cost indirectly.
Convenient
Only power supply is needed for installation. The control system adopts Touch Screen HMI with PLC intelligent program design for convenient and simple operation.
Save Cost
Bottled H2O2 58% solution can get easily in user’s local market.
Reliable sterilization
The chamber adopts aluminum material which has good thermal conductivity to guarantee a stable and even temperature in the chamber. The low temperature storage system provides a stable concentration of H2O2. All these ensure the reliable sterilization.
Safe sealing door
The sterilizer adopts motorized vertical sliding door with reliable sealing function and safe lock device to guarantee safety.
Data management
The flash disk USB can store original cycle data for inquiry. Micro printer prints cycle data timely. There are two types of record methods to guarantee the data is 100% acquirable.
Advanced configuration
The vacuum pump, controller, pressure transmitter and other key components are world famous brands. The sterilizer equipped with multiple programs and bar code identification system (option).
Application Range
This series Hydrogen peroxide low-temperature plasma sterilizers can be used to sterilize the spectral surgical instruments, including the metal and non-metallic devices, as well as the instruments which are sensitive to the dampness and heat.
Medical Device & Materials Suitable for sterilizing by plasma sterilizers
Aluminum
Stainless Steel
Teflon
Silicon
PVC (Polyvinylchloride)
PMMA (Polymethylmetacrylate)
PC (Polycarbonate)
EVA (Ethylvinylacetate)
Polyolefin
Polyurethane
Latex
Polyethylene
Kraton Performance Polymers (polyisoprene rubber)
PP (Polypropylene)
Hard lumen : Length<1,000mm, ID>1mm
Flexible Lumen: Length<12,000mm, ID>1mm
Flexible Single-through Lumen (one-side blocked): Length<1,500mm, ID>2mm
Medical Device & Materials not Suitable for sterilizing by plasma sterilizers
Paper
Cardboard
Organic material
Powder
Wadding
Wet items
Absorptive Material (Cellulose)
Disposable suture materials
Hard Lumen : Length >1,000 mm or ID < 1,
Flexible Lumen : Length >12,000 mm or ID <1
Technical Specification
Sterilization Cycles
Express cycle <40min
Long cycle<60min
Standard cycle<50min
Customized programs:Optional
Sterilization Phases Description
Stages | Descriptions | Time |
Vacuum | An evacuation process that produces a deep vacuum inside the sterilizing chamber. | 4min |
H2O2 Solution Concentrating | Under -180Pa with 40℃ temperature, evaporating the water in H2O2 solution to get 90% H2O2 solution. | 2 min |
Sterilizing 1 | The first process of sterilization. Sterilant is sprayed into the chamber to be activated into the plasma gas generated by the high frequency voltage. Sterilization is carried out through the processes of diffusion and surface contact. | 16-18min |
Sterilizing 2 | A second process to enhance sterilization effect. The sterilizing process is repeated in this stage. Two separate cycles of Plasma Sterilization ensure sterility. | 14-15min |
Finishing | It is a process that returns the inner pressure of chamber to atmospheric pressure before full sterilization process is finished | 2 min |
Chamber: Rectangle chamber of Aluminum alloy, Material: 20mm polymer Isolation material (Durability to 120Cº) eliminating heat loss.
Door system
Motorized, silicon sealed up/down sliding door system
Automatically locked during the sterilization process. After cycle is completed, the door can not be released until the inner pressure and outer pressure are balanced.
If double door structure, the two doors will be interlocked to avoid cross-contamination.
Control system: PLC control with colour Touch Screen HMI panel
Vacuum pump: of oily rotary type, 16M3/h, 0.5KW
Sterilant: needed 90% Hydrogen peroxide 3ml for each cycle, a bottle of 100 ml H2O2 solution(58%) can use 20 cycles.
Filter system: Air passed through HEPA filter to avoid articles second contamination.
Cycle Data: USB connection available for intelligent data management, Micro printer records sterilization cycle data, Error Messages etc.
Alarm system: Visual and Audible Alarm upon the failure form the detect system. the Temperature, Pressure, Sterilant level etc will be detected automatically.
Security: Integrated Emergency Button, Door Safety Sensor, Visual and Audial Error Warnings.
Operating system
By Full Colored Touch Screen Panel.
User can reach to the main menu from coloured touch screen display.
Menu containes the necessary data such as sterilization cylces, real operating graphs, error messages, warnings, program choices, settings, validation and factory settings, short user guide. It has a limited access ( Password protection System ) for authorized users for system security.
Parameters
Chamber volume | 120L | 200L |
Chamber (WxHxD) | 410x450x780mm | 445x550x900mm |
Dimension (WxHxD) | 845x1700x990mm | 932x1775x1098mm |
Door structure | Single door only | Single door/ Double door |
Shelves(2 trays) | Load capacity 10kg | Load capacity 12kg |
Weight | 350kg | 400kg |
Electric power | AC220v/1P/N/E or AC380v/3P/N/E, 50Hz, 3KW | |
H2O2 concentration | Above 90% solution after concentrated automatically from 58% | |
Air intake | Through medical grade HEPA Filter | |
Sterilization temperature | Standards 55 ℃, adjustable range45---55℃ | |
Preheating time at initialization cycle | 30 minutes |